Lind Equipment
Choosing equipment

Should you consider static monitoring?

4 min readGuide 8 of 11

Usually, operators check a static bond or ground by eye. They make sure that the ground clamp and the lead are in place. From time to time, they also check the connection with a resistance meter. This guide explains where that check can fail, how static monitoring helps, and how to decide if your operation needs it.

Why a visual check is not always enough

An operator can use the correct wires and tools and still not get a good bond or ground. If the connection does not reach a conductive surface, the static may still not drain.

An object that is not correctly grounded or bonded can collect a static charge. With the right amount of flammable vapour and a spark, an ignition can occur.

This condition may exist with no sign at all to warn the operator.

How static monitoring helps

Newer electronic verification systems remove the guesswork from bonding and grounding. They give a continuous visual confirmation that the bonded or grounded connection is correct.

This guide compares two of these systems: the G2 Series Ground Monitoring Systems and the StaticSure Portable Static Monitoring System. Both show clearly when a ground connection or bond is in place and static electricity drains. The two systems work on a similar idea. But they have different features, and they use different ways to tell the operator if the connection is correct or not.

Two ways to monitor a static connection

G2 Series Ground Monitoring Systems

G2 Series Ground Monitoring System
G2 Series Ground Monitoring System

G2 Series systems are stationary systems that you mount in place. They are large. They need an electrical input. For use inside hazardous locations, they need a heavy explosion-proof enclosure.

A G2 Series system uses an intrinsically safe monitoring circuit that drives a switching relay. The operator connects the self-releasing clamp and cable to a conducting material. This completes the circuit, and a green light shows that a ground connection is in place. If there is no correct ground, a red light stays on.

The G2 Series monitors two paths for low resistance:

  • The path from the ground unit to the clamp
  • A separate cable connection to actual ground

An interruption in either path (any resistance above 5 ohms) shuts down the system.

You can interlock the system with filling equipment. Then no flammable product can transfer until the ground is in place. For example, the system can let a pump start only when there is a good static ground. If the circuit breaks because the operator releases the grounding clamp, or because of a different ground interruption, the control relay opens. The system then shows a red light. Filling equipment that the system controls also stops until the ground is in place again.

A G2 Series system will:

  • Shut down a pump or valve
  • Sound an alarm
  • Show a red light when conditions are unsafe
  • Show a green light when conditions are safe
  • Open contacts on a computer
  • Indicate that the static path to ground has integrity
  • Receive permissive signals from a computer control

Standard options include an aluminum or a bronze clamp, a straight or a self-coiling cable, and different cable storage and retracting reels.

Operators typically use G2 Series systems in bulk train or truck unloading areas.

StaticSure Portable Static Monitoring System

StaticSure Portable Static Monitoring System
StaticSure Portable Static Monitoring System

StaticSure is a battery-operated, lightweight and portable device. It is intrinsically safe, and you can use it in hazardous locations. StaticSure helps you comply with safety regulations and keep a safe work environment.

Use StaticSure with correct bonding and grounding clamps and cables. It then helps make sure that a static bond is in place before you handle flammable materials.

The intrinsically safe electronics in StaticSure monitor the full connection from the clamp to the ground point. If the connection is not good enough to drain static electricity, StaticSure warns the operator with a very bright, flashing red LED. The LED keeps flashing until the operator corrects the problem and static electricity can drain from the equipment again.

The unit is small. You can use it as a portable unit, or mount it to a wall or a vehicle. Its modular design uses standard industrial static grounding clamps. You can quickly disconnect them and connect them again in the configuration that the work needs.

Operators typically use StaticSure in drumming or other portable operations. Many independent carriers of flammable products also keep a StaticSure in the truck. They use it when the bulk unloading area at a customer site does not have a G2 type system.

Do you need a StaticSure configuration that is not on the product page? Contact us and we will make it for you.

The two systems side by side

G2 Series Ground Monitoring SystemsStaticSure Portable Static Monitoring System
TypeStationary, mounted systemPortable device that you can also mount to a wall or a vehicle
SizeLargeSmall and lightweight
PowerElectrical inputBattery
Hazardous locationsNeeds a heavy explosion-proof enclosure inside hazardous locationsIntrinsically safe, for use in hazardous locations
What it monitorsThe path from the ground unit to the clamp, and a separate cable connection to actual groundThe full connection from the clamp to the ground point
SignalGreen light when the ground connection is in place. Red light when it is not.Very bright red LED that flashes until the operator corrects the problem
Typical useBulk train or truck unloading areasDrumming and other portable operations

Is static monitoring right for you?

Both systems have a role in a correct static grounding process. As a safety manager or facility operator, ask yourself two questions:

  1. How much risk is there in your flammable handling?
  2. A monitoring device lets you be sure that you have a good ground. Is that peace of mind worth it for your employees and your equipment?

Not sure which system suits your site? Contact us.

Key points

  • A visual check of the clamp and lead can miss a connection that does not drain static. Nothing may warn the operator.
  • Static monitoring gives a continuous visual confirmation that the bond or ground connection is correct.
  • G2 Series systems are stationary and mounted. You can interlock them with pumps, so the pump runs only when there is a good static ground.
  • StaticSure is battery operated, lightweight, portable and intrinsically safe. It suits drumming and other portable operations.
  • Base your choice on how much risk there is in your flammable handling.

Products for this guide

Questions about your application?

Call us, email us or send the form, and the right team will get back to you.